说明书 飞利浦SCF922 Avent奶瓶消毒器

需要您的 飞利浦SCF922 Avent奶瓶消毒器 手册吗? 您可以在下面免费查看和下载中文版 PDF 手册。 该产品目前有 4 个常见问题,0 条评论,有 1 票,平均产品评分为 0/100。 如果这不是您想要的手册,请联系我们

您的产品是否出现故障而说明书没能提供解决方案?请前往 Repair Café 以获得免费维修服务。

说明书

Loading…

EN User manual
ZH-CN 使用手册
English
1 Introduction
Congratulations on your purchase and welcome to Philips Avent! To
fully benet from the support that Philips Avent offers, register your
product at www.philips.com/welcome.
2 Important
Read this user manual carefully before you use the appliance and save it
for future reference.
Danger
Never immerse the base, the mains cord or the mains
plug in water or any other liquid.
Failure to follow the descaling instructions may cause
irreparable damage.
Never disassemble the base to avoid the risk of
electric shock.
Warning
This appliance shall not be used by children. Keep the
appliance and its cord out of reach of children.
This appliance can be used by persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Check if the voltage indicated on the appliance
corresponds to the local mains voltage before you
connect the appliance.
Only connect the appliance to an earthed wall socket,
and make sure the plug is rmly inserted in the wall
socket. Keep the mains cord away from hot surfaces.
Do not use the appliance if the plug, the mains cord or
the appliance itself is damaged.
If the mains cord is damaged, it must be replaced by
Philips Avent, a service center authorised by Philips
Avent or similarly qualied persons in order to avoid a
hazard.
There are no serviceable parts inside the electric
steam steriliser. Do not attempt to open, service or
repair the electric steam steriliser by yourself.
The appliance becomes very hot during sterilisation
and may cause burns if it is touched.
Beware of hot steam that comes out of the vent in
the lid or when you remove the lid. Steam can cause
burns.
Do not touch the base, the baskets and the lid during
or shortly after sterilisation to avoid getting burnt.
Only lift the lid by its grip.
Never move or open the appliance when it is in use
or before it has cooled down.
Never place items on top of the appliance when it is
in use.
Only use puried water for sterilisation.
Only use white vinegar according to the user manual
when descaling. Do not put bleach or other chemicals
in the appliance.
Only sterilise baby bottles and other items that are
suitable for steam sterilisers. Check the user manual of
the items you want to sterilise, to make sure they are
suitable for steam sterilisers.
To stop the sterilisation under urgent circumstances,
press the power-off button, and unplug the appliance.
Sterilising for a shorter period of time may affect the
sterilisation efcacy.
This appliance is intended for household use only.
Do not use abrasive or aggressive cleaning agents (e.g.
bleach) or a scouring pad to clean this appliance.
Caution
Never use any accessories or parts from other
manufacturers or that Philips Avent does not
specically recommend. If you use such accessories or
parts, your guarantee becomes invalid.
The appliance is intended to be used indoors. Do not
expose it to extreme heat or direct sunlight.
Always unplug the appliance and let it cool down
before moving or storing it.
Do not sterilise very small items which can fall through
the holes to the heating plate.
Never place items directly on the heating plate when
the appliance is switched on.
Do not use the appliance if it has fallen or is damaged
in any way. Take it to an authorised Philips Avent
service centre for repair.
Always place and use the appliance on a dry, stable,
level and horizontal surface.
Do not place the appliance on a hot surface.
Do not let the mains cord hang over the edge of the
table or worktop on which the appliance stands.
Pour any remaining water out of the appliance after
use and when the appliance has cooled down.
Always unplug the appliance after use.
Environmental conditions, such as altitude above
2500 meters, may affect the sterilising performance of
this appliance.
Electromagnetic fields (EMF)
This Philips appliance complies with all applicable standards and
regulations regarding exposure to electromagnetic elds.
3 Overview
a
Lid
f
Power-on indicator
b
Small basket
g
Power-on button “I
c
Big basket
h
Power-off button “O
d
Heating plate
i
Mains cord
e
Base
Note
The sticker above the power buttons indicates the function of each button. Remove
the sticker before you start using the steriliser.
4 Before first use
When you use the appliance for the rst time, we advise you to let it
complete one sterilisation process with empty baskets.
1 Use a clean baby bottle and pour 90ml/3 uid oz puried water directly
into the heating plate.
90
毫升
90 ml
2 Place the big basket on the base. Adjust the position of the big basket so
that it ts properly on the base.
3 Place the small basket in the big basket. Adjust the position of the small
basket so that it ts properly in the big basket.
a
b
c
d
e
f
g
h
i
4 Place the lid on top of the small basket. Adjust the position of the lid so
that it ts properly on the small basket.
5 Put the plug in the wall socket.
6 Press the power-on button to switch on the appliance.
» The power-on indicator lights up to indicate that the appliance starts
operating.
» A sterilising cycle takes around 10 minutes. When the sterilisation
process is nished, the power-on indicator goes out and the appliance
switches off automatically.
10 分钟
10 mins
7 Unplug the appliance. Wait until the appliance has cooled down
completely, and then remove the lid, the small basket and the big basket,
and wipe them dry.
45 分钟
45 mins
Note
The appliance does not work for about 10 minutes after a sterilising cycle, it needs
to cool down rst.
5 Using the steriliser
Note
To make sure the steriliser stands stable, clip the mains cord into the cord slot in
the bottom of the base.
Only use puried water for sterilisation.
Make sure all parts that need to be sterilised are completely disassembled and
place them in the basket with their openings pointing down to prevent them from
lling up with water.
Only place items which are suitable for sterilising in the steriliser. Do not sterilise
items that are lled with liquid, e.g. a teether with cooling uid.
1 Thoroughly clean the items to be sterilised.
2 Use a clean baby bottle and pour 90ml/3 uid oz puried water directly
into the heating plate.
90
毫升
90 ml
3 Place the big basket on the base. Adjust the position of the basket so that
it ts properly on the base. Then put the bottles in the basket with their
openings pointing down.
4 Place the small basket in the big basket. Adjust the position of the small
basket so that it ts properly in the big basket, then put the accessories in
the small basket.
Tip
When putting larger teats in the small basket, place the teat in the basket rst, then
place the dome cap on the teat, and place the screw ring on the dome cap.
l
5 Place the lid on top of the small basket. Adjust the position of the lid so
that it ts properly on the small basket, and then put the plug in the wall
socket.
1
2
6 Press the power-on button to switch on the appliance.
» The power-on indicator lights up to indicate that the appliance starts
operating.
» A sterilising cycle takes around 10 minutes. When the sterilisation
process is nished, the power-on indicator goes out and the appliance
switches off automatically.
10 分钟
10 mins
7 Unplug the appliance. Wait until the appliance has cooled down
completely, and then remove the lid and the sterilised items from the
baskets.
45 分钟
45 mins
Warning
Be careful when removing the lid, hot steam may come out of the steriliser.
The sterilised items might be hot. Be careful not to get burnt by them.
Note
Make sure you wash your hands thoroughly before you touch the sterilised items.
Tip
After the appliance has cooled down, you can hang the lid on the side of the big
basket. You can also place the lid on a table with the handle facing down, this way
you can put the small basket on the tilted lid to keep it hygienic, and easily take out
the sterilised items in the big basket.
When removing the items from the big and small baskets, you can use a Philips
Avent bottle tong (sold separately).
6 Cleaning
Warning
Do not use abrasive or aggressive cleaning agents (e.g. bleach) or a scouring pad to
clean this appliance.
Never immerse the base, the mains cord or the mains plug in water or any other
liquid.
The steriliser is not dishwasher-proof.
1 Always unplug the appliance after use.
2 After the appliance has cooled down, pour out any remaining water from
the heating plate, and then clean the surfaces around the base and heating
plate with a soft cloth.
3 Clean the big basket, small basket and lid under the tap with some
washing-up liquid, and wipe them dry.
Note
After cleaning, store the steriliser in a clean and dry place.
7 Descaling
When you use the steriliser, small spots may appear on the heating
plate in the base. This is limescale that is building up. The harder the
water, the faster limescale builds up. Descale the steriliser once each
week to ensure that it continues to work effectively. The frequency of
descaling depends on how much limescale is building up.
1 Pour 60ml/2 uid oz of water and 30ml/1 uid oz of white vinegar (6-8%
acetic acid) into the heating plate.
2 Leave the solution in the heating plate until the limescale has resolved. The
process takes about 20 minutes, but should not be longer than 1 hour.
3 Empty the heating plate, thoroughly rinse it and wipe it with a soft cloth.
Note
When descaling, do not put the plug in the wall socket.
After descaling, store the steriliser in a clean and dry place.
8 Recycling
Do not throw away the product with the normal household waste
at the end of its life, but hand it in at an ofcial collection point for
recycling. By doing this, you help to preserve the environment.
9 Guarantee and service
Philips Consumer Lifestyle guarantees its products under correct usage
for a period of two years after the date of purchase. If any defect
due to faulty materials and workmanship occurs within this two-year
guarantee period, Philips Consumer Lifestyle will repair or replace
the product at its expense. For repair or replacement, make sure to
provide convincing proof, for instance by means of a receipt, that the
day on which service is claimed is within the guarantee period.
The guarantee only covers the base and its electrical components. It
does not cover non-electrical parts, accessories and consumable parts.
The guarantee does not cover shipping and handling fees, and on-site
services fees either.
If you need service or information, or if you have a problem, please
contact the Philips Avent Service Center in your country.
Website: http://www.philips.com/support
SCF922
始终如一地为您提供帮助
在以下网站上注册产品并获得支持
问?
请联系飞
www.philips.com.cn/welcome
如果需要帮助,请联络
Philips Avent
中国大陆咨询电话:
4008 800 008
ZHCN
6&)
ᮮѱ฿஧ߪঝၶཊᗕ෇๊ർᩑ̊֩
ڿԵ
ᮜ߳ၶԀ
ᮜ߳ᮓ
ᮜ߳ᣘЍҝ࿾
ၪ̊ஹ
న̊֩ಝ૩ځಉ*%*%
ѷᤨ
̊ڔ
+]
:
ឣᜬ̊֩నͧ
ˊځูරຑࢪ
9
0844 33 80 489
5 pence/minute
(mobile rates may vary) UK only
GB
出版日期:
2016-8-31
使用产品前请仔细阅读本使用说明书
保留备用
© 2016 Koninklijke Philips N.V.
保留所有权利
4241 210 44974
下载中国版说明书 (PDF, 10.24 MB)
(鉴于环保,请在真正必要时才打印此说明书)

Loading…

常见问题

请给产品评分,告知您对飞利浦SCF922 Avent奶瓶消毒器看法。您是否希望分享对该产品的体验或提出问题?请在页面底部留言。
您对飞利浦SCF922 Avent奶瓶消毒器满意吗?
没有
0%
100%
1 投票

加入有关该产品的对话

您可以在这里分享您对 飞利浦SCF922 Avent奶瓶消毒器 的看法。 如果您有疑问,请先仔细阅读手册。 可以使用我们的联系表索取手册。

有关本说明书的更多信息

我们知道,为您的 飞利浦SCF922 Avent奶瓶消毒器 提供纸质手册是件好事。 您随时可以从我们的网站下载该手册并自行打印。 如果您想要原始手册,我们建议您联系Philips。 他们也许能够提供原始手册。 您是否正在寻找其他语言版本的 飞利浦SCF922 Avent奶瓶消毒器 手册? 在我们的主页上选择您的首选语言并搜索型号以查看我们是否有可用。

规格

品牌 Philips
模型 SCF922 Avent
类别 奶瓶消毒器
文件类型 PDF
文件大小 10.24 MB

飞利浦奶瓶消毒器 的所有手册
奶瓶消毒器 的更多手册

关于 飞利浦SCF922 Avent奶瓶消毒器 的常见问题

我们的支持团队将搜索有用的产品信息并回答常见问题。如果您在常见问题中发现不准确的回答,请使用联系表格告知我们。

我每天都对瓶子消毒,但瓶子里仍然有牛奶残留。这是为什么? 验证

在消毒之前,一定要先清洗瓶子。消毒器用于杀死细菌,但不能代替刷子或洗碗机。

有帮助 (92) 阅读更多

我应该多久为消毒锅除垢一次? 验证

定期使用消毒器时,应至少每 4 周除垢一次,具体取决于您所在区域的水质。

有帮助 (20) 阅读更多

我的消毒锅底部变成棕色,我该怎么办? 验证

这可能是水垢堆积,表明您应该为灭菌器除垢。请参阅特定灭菌器的手册,了解如何为您的型号除垢。

有帮助 (14) 阅读更多

灭菌后我可以手动干燥瓶子吗? 验证

不,不建议这样做。留在瓶子上的水是无菌的,不含细菌。通过手动干燥瓶子,将会添加新的细菌,使瓶子不再无菌。

有帮助 (4) 阅读更多
说明书 飞利浦SCF922 Avent奶瓶消毒器

相关产品

相关类别